Boiler buderus 60 kW gas consumption.

Delivery of goods in Moscow and the Moscow region is carried out by our own trucks within a pre-agreed timeframe and depends on the weight and category of your product.

The cost of delivery of goods weighing more than 1500 kg, please check with the manager.

* Free delivery of goods of the category "Light" is carried out when ordering from 1000 rubles.

We deliver orders from Monday to Saturday from 10:00 to 18:00. On the day of delivery, the driver will contact you 1.5 hours before arrival. If delivery at other hours is convenient for you, please check with the manager. Delivery after 18:00 is charged separately. Each extra hour after 18:00 + 400 rubles to the cost of delivery.

Pickup of goods is available by prior arrangement, after confirmation of receipt of the order at the pickup warehouse.

Please note that upon receipt of the goods legal entities authorization is required for individuals- an identity document.

DELIVERY TO THE REGIONS OF RUSSIA

Delivery to the regions of Russia (with the exception of Moscow and the Moscow region):

Delivery of orders to the regions is carried out through transport companies. We deliver and ship your order to the carrier. You can independently calculate the cost of shipping an order to your region; for this, almost every transport company has an online calculator on the official website. You need to enter certain values ​​(weight and volume, number of pieces), points of departure and destination!

Upon receipt of the order, you will need to pay the cost transport services. The cost of delivery to the warehouse of the transport company is calculated according to local delivery rates.

Below are the websites of the most popular and reliable transport companies:

# Transport companies
1 Business Line
2 PEC
3 ZhelDorExpedition
4 ZheldorAlliance
5 BaikalService
6 WHALE

Also delivery can be carried out by any other transport company of your choice.

If for some reason you want us to send your order to another transport company, just tell us its coordinates, and we will send the goods as quickly as possible.

Delivery to the regions of the Russian Federation is made only after full prepayment of the cost of the purchased goods (receipts Money to the store account).

Floor standing gas cast iron heating boiler " Buderus Logano G234X (WS) 60-7" with a capacity of 60 kW with an atmospheric burner in 2017 appeared in an updated version - with modern automation of the standard EMS Plus and striking industrial design from Buderus. This new generation boiler has retained the main qualities inherent in its predecessor, such as high performance at low costs, reliability, efficiency, compactness. Works on both natural and liquefied gas. The boiler is designed for heating large buildings, as it can be used to organize economical heating when high power is required. In combination with high-quality Buderus floor-standing water heaters of the Logalux ST and Logalux SU series, it allows you to create a comfortable hot water system.

The premix atmospheric gas burner supplied at the factory does not have a fan, which ensures quiet operation. There is no need for additional noise suppression measures during the heating mode. The burner operates in fully automatic mode, the ignition is electric and does not require additional gas consumption.

Low-temperature heating boiler "Logano G234X (WS) 60-7" is equipped with an efficient heat exchanger with 7 sections, made of high quality gray cast iron GL 180M. The sections are ideally matched to the design of the boiler block and have special ribs, due to which there is an intensive heat transfer of the heating surfaces. The boiler is equipped with 80 mm thick thermal insulation, which, together with the cladding, prevents energy losses.

The new boiler model "Logano G234X (WS)" is designed specifically for installation modern system control "Buderus Logamatic MC110" standard EMS Plus. This automation is optionally equipped with a controller "RC 310" or "BC 30 E" with touch screen and full text menu. Such a system allows you to work in weather-dependent mode, controls the boiler and indirect heating boiler, recirculation line, 3-way valve, and also informs about the current status, selected functions, errors. The control is carried out by a 0-10 V signal. The setting of all options is intuitive and very simple - according to the “Push and turn” principle. All control functions are coordinated with the system hydraulics. The control system can be expanded with additional modules: mixing modules, Internet connection module, cascade module with the ability to control up to 4 boilers, modules for solar systems. For complex systems it is recommended to use professional automation of the new generation "Logamatic 5000". The control system is not included in the delivery of the boiler and must be ordered separately.

Boiler "Logano G234X (WS)" is supplied fully assembled, with casing and gas burner, which saves a lot of time and costs for installation and quick start-up. The quick mounting system for the heating circuit for connection to the boiler or wall mounting is adapted to the respective hydraulic scheme. The tank water heater is conveniently connected to the boiler using a connecting pipeline with a loading pump and a non-return valve. The design of the burner has no moving parts, and its reconfiguration for other types of gas is as simple as possible. Since the combustion process takes place practically without the formation of soot, the amount of maintenance and cleaning work is reduced to a minimum. This boiler is pre-set for natural gas. For conversion to LPG, a special conversion kit is used. (optional).

The main features and advantages of the Logano G234X (WS) 60-7 boiler:

  • Rated heating output (at 80/60 °C): 60 kW
  • Heat exchanger made of special gray cast iron
  • 7 cast iron sections perfectly matched structurally
  • Intensive heat dissipation of heating surfaces due to special fins
  • High standardized efficiency at maximum power (at 80/60 °C): 92.2%
  • Versions for operation on natural or liquefied gas
  • Fully automatic atmospheric burner with electrical ignition
  • Burner control SAFe
  • Ionization flame control and double solenoid valve
  • Low emissions of harmful substances
  • Silent and reliable operation
  • Combustion chamber closed on all sides
  • The presence of a gas pipeline under the casing of the boiler for easy connection of gas from behind
  • Richer functionality through combinations with control systems EMS and EMS Plus from the Buderus program (optional equipment)
  • Simple and convenient control
  • Low-temperature economical mode of operation, which reduces heating costs
  • Infinitely variable boiler water temperature control without base temperature
  • Can be combined with adjacent Logalux ST and Logalux SU boilers
  • 80mm thermal insulation to keep heat loss to a minimum
  • Quick installation - the boiler is already fully assembled with casing
  • Compact dimensions - it is convenient to carry through the openings and place in the boiler room
  • Easy installation and maintenance due to uncomplicated design
  • Case of a new original "industrial" design in black and blue
  • Modern technology High Quality
  • Large selection of accessories adapted to the boiler for quick installation

Buderus Logano G234 60 kW- a heating boiler equipped with an atmospheric gas burner with premixing. It is an ideal choice for heating large buildings. With it, you can very economically organize the supply of heat in situations where high power is required. In combination with a DHW cylinder, it is easy to realize a comfortable domestic hot water system.

The principle of atmospheric combustion is as follows: gas is automatically supplied to the burner along with the atmospheric air necessary for combustion. You do not need to use an electric fan, as in other heating boilers. Since the fuel is burned in separate flares, the flame does not come into contact with the burner tube, it does not heat up and therefore lasts longer.

Buderus Logano G234 60 kW - hydraulic circuits using boiler combinations with various burners and control systems:

  1. Logamatic 2107: single-stage burner - storage tank - circulation pump. Complete with FM 241: heating circuit with mixer. Complete with FM 242: 2-stage or modulating burner. Complete set with FM 244: solar collector.
  2. Logamatic 4211: single, two-stage or modulating burner - storage tank - circulation pump. Complete with FM 442: two heating circuits with mixer. Complete with FM 445: system with external heat exchanger. Complete with FM 443: solar collector module. Equipped with FM 446: single EIB interface electronic system home management. Equipped with FM 448: general error message.
  3. Logamatic 2101 (operation with constant boiler water temperature): single-stage burner.

Buderus Logano G234 60 kW - advantages of a low-temperature gas boiler:

  • Ionization flame control and double solenoid valve;
  • Low emission of harmful substances;
  • Quiet operation;
  • Compact dimensions and the ability to install a water heater to the right or left of the boiler;
  • High efficiency (up to 93%), due to the intensive heat transfer of the heating surfaces of the cast-iron heat exchanger;
  • Ease of installation and maintenance;
  • Reliability and durability of the boiler structure made of gray cast iron;
  • Ease of combining and selecting control systems and water heaters from the Buderus program;
  • Highly efficient thermal insulation;
  • There are no restrictions on the minimum boiler water temperature.

Buderus Logano G234 60 kW - boiler purpose:

It can be used to heat buildings up to 600 m2, meeting average heat requirements. With additional equipment, the boiler can be connected to the DHW circuit.

Heating appliances with a power of 60 kW are ideal for heating a country cottage, commercial or industrial property. It can run on natural and liquefied gas, so it is suitable for any facility, including those that do not have a central gas supply.

Specifications

  • Rated thermal power (kW): 60;
  • Dimensions HxWxD (mm): 1204x830x726;
  • Boiler water volume (l): 31;
  • Without control system;
  • Weight (kg): 310;
  • Permissible overpressure (bar): 4;

Buderus gas boilers have proven themselves in the market on the positive side for a long time. They are produced according to German technology, so the quality of the manufactured equipment remains at a high level. The company manufactures a wide range the lineup gas units with different characteristics.

Modern Buderus boilers have high efficiency and the possibility of autonomous operation. The consumer can choose an option with any power for heating apartments, cottages, warehouses, enterprises, etc.

Consider gas boiler buderus 60 kw. The Buderus Logano G234X-60 model has such power; it is designed for heating cottages, private houses up to 560 m². In apartments, this device is not used, since it is equipped with an open combustion chamber. This unit has a sectional cast iron heat exchanger that can last about 15 years. It is important that cast iron corrodes half as much as a steel element.

During the day, cast iron is corroded by a 10% solution of sulfuric acid in the amount of 680 g / m², and in distilled water - 5.51 g / m². For steel, these figures are higher. Boilers with a cast-iron heat exchanger are operated even at low temperatures. This unit runs on main gas, but if desired, you can also connect liquefied gas from a cylinder, for which you will need to purchase jets.

The boiler control system is powered by electricity, so you need to connect it to electrical network 220 V. To protect the unit from power surges and extend its service life, it is recommended to install a stabilizer.

The presence of an open combustion chamber implies a visible flame, air is taken from the room, and smoke is removed through a stationary chimney.

This model of a gas boiler with a capacity of 60 kW is highly economical, most of its analogues consume more fuel under the same operating conditions. The maximum consumption of natural gas of this model is 6.4 m3/hour, the largest consumption of liquefied fuel is 4.5 kg/hour. The boiler efficiency is 93%. The unit has one circuit and works only for heating. It does not provide hot water.

Below is a table of the main specifications buderus 60kw Logano G234X models.

If necessary, the owner of the buderus 60 kW boiler will be able to expand the configuration of the control system with additional functions. Distinctive features of this model are also:

  • possibility of combination with various systems control program Buderus Logamatic 2101, Logamatic 2107, Logamatic 4211;
  • construction with perfectly matched sections made of high-quality cast iron;
  • combination with adjacent storage tanks Logalux ST and Logalux SU with a capacity of 150, 200 and 300 liters using connecting pipelines;
  • fast and convenient installation;
  • easy conversion to other types of gas;
  • burner design without movable elements;
  • black panel design makes it easy to fit the unit into any style of room;
  • low noise.

The Buderus Logano G234-60 is designed to work reliably even at a gas pressure of 10 mbar. This model has the following control system features: weather-compensated operation, internet connection, control of the recirculation line, solar system, mixing valve, 3-way tap.

How to equip a boiler room for the Buderus Logano G234-60 boiler is described in the video.

Buderus Logamax GB112-60

Another well-known Buderus gas boiler model with a capacity of 60 kW is the Logamax GB112-60. Unlike the previous model, it is hung on the wall, and it has more compact dimensions. This model is capable of heating cottages or utilities with cascading up to 470 kW.
This boiler model has the ability to smoothly change the power from 39% to 100%. The unit has excellent efficiency from 98% to 109%, has a smooth steel heat exchanger made of finned tubes with large area heating. However, this model does not include an expansion tank. You will have to choose it yourself. The condensing boiler can be equipped with a control system and storage tanks Logalux HC70/110, S120.

In order for the boiler to last as long as possible, the combustion air must meet the following requirements:
do not use or store cleaning products containing chlorine in the room where the boiler is located;
the air must not contain aggressive substances, such as fluorine and chlorine compounds.
Harmful substances in the air affect the corrosive processes.
If in the room where the gas boiler is located, they carry out construction works, the following steps should be taken:
turn off and cover the unit;
before starting the device, do not forget to clean the dusty burner.
Water quality also plays a significant role in extending the life of the unit, as well as in improving the efficiency, reliability and performance of the heating system. If there is an increased level of calcium in the water used, lime deposits appear on the surface of the heat exchanger, preventing the water from heating. As a result, the temperature of the heat exchanger increases and thermal loads appear.
If the water is too hard, it is necessary to put a filter device on the inlet.


To obtain the desired temperature in the room, it is necessary to fully open the thermostatic valves. If the optimum heat level is not reached for a long time, set the temperature on the controller even higher.

Note! If in heating system often add water, it will fail faster due to corrosion and scale.

If the gas boiler is temporarily not in operation, the coolant is drained from the system.
Maintenance and cleaning of the boiler must be carried out once a year. In this case, it is required to check the performance of the entire system. Maintenance, installation, connection of gas and electricity, the first start-up of the Buderus 60 kW unit must be carried out only by a specialist specialist company that is authorized to carry out such work.

Off-gas control device

The boiler can be equipped with a flue gas control system, for example when the unit is operated in a rooftop boiler room. This device turns off the gas supply if the fuel goes into the room where the unit is installed, as a result of which the burner is turned off. After 15 minutes, it turns on again. If the device operates too often, then there is a malfunction in the chimney. Then you should call a specialist.

What to do in case of burner failure?

If any malfunction occurs in the operation of the burner, the alarm button for suppressing boiler interference lights up. In this case, system malfunctions are displayed. To continue the operation of the unit, press the burner noise suppression button and try to light it again. If the burner does not turn on after several attempts, call a specialist.

Note! You can press the noise reduction button up to three times. If this is done more often, the ignition transformer of the burner can be damaged.

When operating buderus gas boilers with a power of 60 kW, they should be located in the basement, in the attic or in specially equipped boiler rooms. Such units are not equipped with a hot water circuit, but you can always purchase additional accessories and use them to get a system that meets your needs.

Buderus Logano G234-60 G20 60kW, atmospheric burner, single circuit

Logano G234

  • Boiler block design with perfectly matched sections
  • Boiler sections made of high quality cast iron GL 180 M
  • Combustion chamber closed on all sides
  • Intensive heat dissipation of heating surfaces due to special fins
  • Easy installation and maintenance due to uncomplicated design
  • Fully automatic operation with electric ignition, no additional gas consumption required for ignition
  • For ease of connecting gas to the boiler at the back, under its casing, there is gas pipeline
  • 80 mm thermal insulation reduces heat loss to a minimum
  • The heating boiler is fully assembled with casing - this saves time and installation costs
  • Compact dimensions - an advantage when passing through openings and when placed in a boiler room
  • Various combinations with control systems and storage tanks to suit every need
  • Big choice additional equipment for quick installation adapted to a specific boiler
Low Emission Premix Gas Burner
  • Fully automatic burner with electrical ignition
  • Ionization flame control and double solenoid valve
  • New system combustion reduces the emission of harmful substances
  • The Venturi tube of the gas burner ensures almost 100% mixing of fuel with air. During the combustion process, many small individual flames are formed without a high-temperature core. Therefore, in such gas burners, the combustion temperature is significantly reduced. In addition, the short flame of these centers easily breaks away from the burner rod, reducing the heat load on it.
Supply
  • Heating boiler - natural gas E (G 20), with thermal insulation and boiler lining - 1 box
  • Parts for conversion to liquefied gas P (G31) (optional) - 1 box
  • Control system (optional) - 1 box
Design Guidelines

Hydraulic resistance of the boiler to water

Fuel

The gas burners are factory set, comparable to the EE-H method, for natural gas E (G20). The gas type can be reset to LPG P (G31) at any time using the conversion parts (accessory). It is not possible to change over to city gas. The supplied gas pressure (supply pressure is the static overpressure of the gas relative to atmospheric when it is exhausted at the connection point of the gas appliance) must be in the following range:

The maximum supply pressure for natural gas operation can be 25 mbar. For higher gas supply pressures, an additional gas pressure regulator must be installed on the burner. The maximum test pressure is 150 mbar.

Flue gas temperature / flue connection

The required pressure for all boiler sizes is at least 3 and maximum 10 Pa.
In order to more precisely adjust and maintain the draft in the chimney, as well as to organize the ventilation of the chimney itself, it is recommended - after agreement with an authorized chimney specialist - to install and adjust an additional air regulator (draft limiter). The cross section of the auxiliary air regulator depends on the effective height and cross section chimney.

Flue gas stop valve

If desired, a flue gas shut-off valve is available as an option. A flue gas shut-off valve installed upstream of the draft interrupter operates more efficiently than one installed after it.

Underfloor heating systems

In floor heating systems using oxygen-permeable plastic pipes (DIN 4726), a heat exchanger must be installed between the boiler and the floor heating system.

Hot water preparation

The heating boiler can work with any water heater tank. Combinations of the boiler with tanks of the Logalux ST/SU series have particular advantages.

General provisions

  • For boilers that must be equipped with a flue gas control system in accordance with the FeuVO of the respective federal state, accessories can be supplied
  • For version B11 (without flue gas control system), the boiler may only be installed in rooms that have the required ventilation to the atmosphere and have a self-closing and hermetic door, e.g. in boiler rooms
  • For version B11 BS (with flue gas monitoring system), the boiler can be installed in apartments or similar places
  • To ensure the functioning of the boiler, all connections must be made in the places specified for them.
  • When installing a gas boiler operating on liquefied gas below ground level, it is recommended to install a second solenoid valve. Switchgear to control the solenoid valve can be supplied as an option
  • In systems with underfloor heating, with several heating circuits, and in systems with large water volumes, local operating conditions, installation of a mixer for regulating heating circuits.
sightseeing

To ensure environmentally friendly and trouble-free operation and in accordance with § 10 EnEV, regular inspections of the boiler and burner are recommended.

Boiler installation room

When installing the boiler, the specified minimum distances (indicated in parentheses) must be observed. For the convenience of installation, service and maintenance work, it is necessary to maintain the recommended distances from the walls.

The room where the equipment is to be installed must be protected from the cold and well ventilated. In addition, care must be taken to ensure that the combustion air is not contaminated with dust or halogenated hydrocarbons. Halogenated hydrocarbons of all kinds are found, for example, in aerosols, solvents and cleaners, varnishes, paints, and adhesives.

Modern universal boiler concept

  • Low-temperature boiler according to DIN EN 297 with continuously variable boiler water temperature control without base temperature (minimum boiler water temperature)
  • Versions for natural gas E or LPG P
  • Boiler design with perfectly matched sections made of high quality cast iron
  • Proven and reliable heating boiler with cast iron heat exchanger and atmospheric gas burner
  • Can be combined with adjacent storage tanks Logalux ST and Logalux SU from the Buderus range
  • Can be combined with various control systems from the Buderus program
  • High standardized utilization rate (93%) and low emissions
Operation with reduced noise and low emissions
  • Atmospheric premix gas burner without fan
  • Heating mode without additional noise reduction measures
  • The indicators of harmful emissions are below the boundary values ​​​​of the environmental requirements "Blue Angel"
  • CE mark
Simple and convenient control
  • Control functions adapted to the system hydraulics
  • Easy setting of all control system functions (Push and Turn)
  • It is possible to expand the configuration of all control systems of additional modules
Quick installation, commissioning and Maintenance
  • Quick mounting system for the heating circuit adapted to the respective hydraulic circuit for connection to the boiler or wall mounting
  • Convenient connection of Logalux ST and Logalux SU storage tanks with a capacity of 150, 160, 200 and 300 liters to the boiler thanks to the boiler-to-water heater connection pipe with charging pump and non-return valve
  • Burner design without moving parts
  • Easy conversion of the burner to other types of gas