Buderus logano g234 60kw specifications.

Gas boilers Buderus companies have proven themselves on the market with a positive side for a long time. They are produced according to German technology, so the quality of the equipment produced remains at a high level. The company produces an extensive the lineup gas units with different characteristics.

Modern Buderus boilers have high efficiency and the ability to work independently. The consumer can choose an option with any power for heating apartments, summer cottages, warehouses, enterprises, etc.

Consider a gas boiler buderus 60 kW. This power is possessed by the Buderus Logano G234X-60 model, it is intended for heating summer cottages, private houses with an area of ​​up to 560 m². This device is not used in apartments, since it is equipped with an open combustion chamber. This unit has a cast iron sectional heat exchanger that can last for about 15 years. It is important that cast iron corrodes half as much as a steel element.

During the day, cast iron is corroded by a 10% solution of sulfuric acid in the amount of 680 g / m², and in distilled water - 5.51 g / m². In steel, these indicators are higher. Boilers with a cast iron heat exchanger operate even at low temperatures. This unit runs on main gas, but if you wish, you can also connect liquefied gas from a cylinder, for which you will need to purchase jets.

The boiler control system is powered by electricity, therefore it is necessary to connect it to electrical network 220 V. To protect the unit from voltage surges and extend its service life, it is recommended to install a stabilizer.

The presence of an open combustion chamber implies a visible flame, air is taken from the room, and smoke is removed by a stationary chimney.

This model of a 60 kW gas boiler is highly economical, most of its analogues consume more fuel under the same operating modes. The maximum consumption of natural gas for this model is 6.4 m3 / h, the highest consumption of liquefied fuel is 4.5 kg / h. The boiler efficiency is 93%. The unit has one circuit and operates only for heating. He does not provide hot water supply.

Below is a table of the main characteristics buderus 60 kw Logano G234X models.

If necessary, the owner of the buderus 60 kW boiler will be able to expand the complete control system with additional functions. Distinctive features this model are also:

  • possibility of combination with different systems control software Buderus Logamatic 2101, Logamatic 2107, Logamatic 4211;
  • construction with perfectly matched sections made of high quality cast iron;
  • combination with the adjacent Logalux ST and Logalux SU water heaters with a capacity of 150, 200 and 300 liters by means of connecting pipes;
  • quick and easy installation;
  • easy conversion to other types of gas;
  • burner design without moving parts;
  • design with black panel makes it easy to fit the unit into any style of room;
  • low noise.

The Buderus Logano G234-60 is designed to operate reliably even with gas pressures of 10 mbar. This model has the following control system capabilities: work in weather-dependent mode, Internet connection, control of the recirculation line, solar system, mixing valve, 3-way valve.

How to equip a boiler room for a Buderus Logano G234-60 boiler is described in the video.

Buderus Logamax GB112-60

Another well-known Buderus gas boiler model with a capacity of 60 kW is the Logamax GB112-60. Unlike the previous model, it is hung on the wall and has more compact dimensions. This model is capable of heating cottages or public utilities with cascade connections up to 470 kW.
This boiler model has the ability to smoothly change the power from 39% to 100%. The unit has excellent efficiency from 98% to 109%, has a smooth steel heat exchanger made of finned tubes with large area heating. However, this model does not include an expansion tank. You will have to pick it up yourself. The condensing boiler can be equipped with a control system and water heaters Logalux HC70 / 110, S120.

In order for the boiler to last as long as possible, it is necessary that the combustion air meets the following requirements:
do not use or store in the room where the boiler is located, chlorine-containing cleaning agents;
the air must be free from aggressive substances such as fluorine and chlorine compounds.
Harmful substances in the air affect corrosive processes.
If in the room where the gas boiler is located, carry out construction works, the following measures should be taken:
switch off and cover the unit;
remember to clean the dusty burner before starting the unit.
Water quality also plays a significant role in extending the life of the unit, as well as improving the efficiency, reliability and performance of the heating system. If the level of calcium in the water used is high, lime deposits form on the surface of the heat exchanger, which prevents the water from heating. As a result, the temperature of the heat exchanger increases and thermal stresses appear.
If the water is too hard, it is necessary to put a filter device on the inlet.


To obtain the required room temperature, the thermostatic valves must be fully open. If the optimal heat level is not reached for a long time, set the temperature on the regulator even higher.

Note! If in heating system often add water, then it will fail faster due to corrosion and the appearance of scale.

If the gas boiler is temporarily not in operation, the coolant is drained from the system.
Boiler maintenance and cleaning must be carried out once a year. In this case, it is required to check the performance of the entire system. Maintenance, installation, connection of gas and power supply, the first start-up of a Buderus 60 kW unit should be carried out only by a foreman of a specialized company who has permission to carry out such work.

Flue gas monitor

The boiler can be equipped with a flue gas monitoring system, for example, when the unit is operated in a rooftop boiler room. This device turns off the gas supply if fuel goes into the room where the unit is installed, as a result of which the burner is turned off. After 15 minutes, it turns on again. If the device works too often, then there is a malfunction in the chimney. Then you should call a specialist.

What to do if the burner malfunctions?

If any malfunction occurs in the operation of the burner, the signal button for suppressing noise of the boiler lights up. In this case, the display shows system malfunctions. To continue operating the unit, press the burner suppressor button and try to ignite it again. If the burner does not start after several attempts, call a specialist.

Note! You can press the Noise Cancel button up to three times. Doing this more frequently can damage the ignition transformer of the burner.

When operating buderus gas boilers with a capacity of 60 kW, they should be located in the basement, in the attic or in specially equipped boiler rooms. Such units are not equipped with a hot water circuit, but you can always purchase additional accessories and use them to get a system that meets your needs.

Delivery of goods in Moscow and the Moscow region is carried out by our own trucks within a pre-agreed time frame and depends on the weight and category of your product.

The cost of delivery of goods weighing more than 1500 kg, please check with the manager.

* Free delivery of goods of the "Light" category is carried out when ordering from 1000 rubles.

We deliver orders from Monday to Saturday from 10:00 to 18:00. On the day of delivery, the driver will contact you 1.5 hours before arrival. If delivery is convenient for you at other hours, please check the conditions with the manager. Delivery after 18:00 is charged separately. Each extra hour after 18:00 + 400 rubles to the cost of delivery.

Pickup of goods is available by prior arrangement, after confirmation of the receipt of the order at the pickup warehouse.

Please note that upon receipt of the goods legal entities a power of attorney is required, for individuals- an identity document.

DELIVERY TO REGIONS OF RUSSIA

Delivery to the regions of Russia (except for Moscow and the Moscow region):

Delivery of orders to the regions is carried out through transport companies. We deliver and ship your order to the carrier. You can independently calculate the cost of delivering an order to your region; for this, almost every transport company on the official website has an online calculator. You need to enter certain values ​​(weight and volume, number of places), points of departure and destination!

Upon receipt of the order, you will need to pay the cost transport services... The cost of delivery to the warehouse of the transport company is calculated according to the rates of local delivery.

Below are the websites of the most popular and reliable transport companies:

# Transport companies
1 Business Line
2 PEC
3 ZhelDorExpedition
4 ZheldorAlliance
5 BaikalService
6 WHALE

Also, delivery can be carried out by any other transport company of your choice.

If for some reason you want us to send your order by another transport company, just tell us its coordinates, and we will send the goods as quickly as possible.

Delivery to the regions of the Russian Federation is made only after full prepayment of the cost of the purchased goods (receipt Money to the account of the store).

Article: 8732204655

Documentation

Logano G234

  • Boiler block design with perfectly matched sections
  • Boiler sections made of high quality cast iron GL 180 M
  • Combustion chamber closed on all sides
  • Intensive heat transfer from heating surfaces due to special ribbing
  • Ease of installation and maintenance due to uncomplicated design
  • Fully automatic operating mode with electric ignition, no additional gas consumption is required for ignition
  • For ease of connecting gas to the boiler from behind, there is a gas pipeline under its casing
  • Thermal insulation 80 mm thick reduces heat loss to a minimum
  • The heating boiler is completely assembled together with the casing - this saves time and costs for installation
  • Compact dimensions - an advantage when carrying through openings and when placed in a boiler room
  • Various combinations with control systems and hot water tanks - to meet any need
  • Big choice additional equipment for quick installation, adapted to the specific boiler
Low Emission Premix Gas Burner
  • Fully automatic burner with electric ignition
  • Ionisation flame control and double solenoid valve
  • The new combustion system reduces the emission of harmful substances
  • The venturi of the gas burner ensures almost 100% mixing of fuel with air. During the combustion process, many small, separate fires without a high-temperature core are formed. Therefore, in such gas burners, the combustion temperature is significantly reduced. In addition, the short flame of these foci easily breaks off the burner rod, reducing the heat load on it.
Supply
  • Heating boiler - for operation on natural gas E (G 20), with thermal insulation and boiler casing - 1 box
  • Parts for conversion to LPG P (G31) (optional) - 1 box
  • Control system (optional) - 1 box
Design guidelines

Boiler water resistance

Fuel

Gas burners have been factory set, comparable to the EE-H method, for natural gas E (G20). You can reset the gas type to LPG P (G31) at any time using the conversion parts (optional). Conversion to city gas is not possible. The supplied gas pressure (the supplied pressure is called the static overpressure of the gas relative to atmospheric when it expires at the connection point of the gas appliance) must be in the following range:

The maximum supply pressure for natural gas operation is 25 mbar. For higher gas supply pressures, an additional gas pressure regulator must be installed on the burner. The maximum test pressure is 150 mbar.

Flue gas temperature / chimney connection

The required pressure for all boiler sizes is a minimum of 3 and a maximum of 10 Pa.
For a more precise adjustment and maintenance of the draft in the chimney, as well as for the organization of ventilation of the chimney itself, it is recommended - after consultation with an authorized chimney specialist - the installation and adjustment of an additional air regulator (draft limiter). The cross-section of the auxiliary air regulator depends on the effective height and cross section chimney.

Flue gas shut-off valve

If desired, a flue gas shut-off valve is available as an option. A flue gas shut-off valve upstream of the draft interrupter is more efficient than a downstream one.

Installations with underfloor heating

In underfloor heating systems using oxygen-permeable plastic pipes (DIN 4726), a heat exchanger must be installed between the boiler and the underfloor heating system.

Preparing hot water

The heating boiler can be operated with any hot water storage tank. Combinations of the boiler with the Logalux ST / SU series tanks have particular advantages.

General Provisions

  • For boilers that must be equipped with a flue gas monitoring system in accordance with the FeuVO of the respective federal state, accessories can be supplied
  • For version B11 (without flue gas monitoring system), the boiler may only be installed in rooms that have the required ventilation to the atmosphere and also have a self-closing and sealed door, for example, in boiler rooms
  • For version B11 BS (with flue gas monitoring system), the boiler can be installed in apartments or similar places
  • To ensure the functioning of the boiler, all connections must be made in the places specified for them.
  • It is recommended to install a second solenoid valve when installing a gas-fired boilers fired with liquefied gas below ground level. Switchgear for controlling the solenoid valve can be supplied as an option
  • In installations with underfloor heating, with several heating circuits, as well as in installations with a large volume of water, it is necessary, based on the local operating conditions, to install a mixer to regulate the heating circuits.
Inspections

To ensure environmentally friendly and trouble-free operation and in accordance with the regulation of § 10 EnEV, it is recommended to carry out regular inspections of the boiler and burner.

Boiler room

When installing the boiler, observe the minimum distances indicated (indicated in brackets). For the convenience of installation, service and maintenance, it is necessary to maintain the recommended distances from the walls.

The installation room must be protected from the cold and well ventilated. In addition, care must be taken to ensure that the combustion air is not contaminated with dust or halogenated hydrocarbons. Halogenated hydrocarbons of all types are found, for example, in aerosols, solvents and cleaners, varnishes, paints and adhesives.

Modern, versatile boiler concept

  • Low-temperature boiler to DIN EN 297 with continuously variable boiler water temperature control without base temperature (minimum boiler water temperature)
  • Versions for operation on natural gas E or LPG P
  • Boiler construction with perfectly matched sections made of high quality cast iron
  • Proven and reliable heating boiler with cast iron heat exchanger and atmospheric gas burner
  • Combines with the adjacent Logalux ST and Logalux SU hot water tanks from the Buderus program
  • Combines with various control systems from the Buderus program
  • High standardized utilization rate (93%) and low emissions of harmful substances
Work with reduced noise level and low emission of harmful substances
  • Premixed atmospheric gas burner without fan
  • Heating mode without additional noise suppression measures
  • Indicators of harmful emissions are below the limit values ​​of environmental requirements "Blue Angel"
  • CE mark
Simple and convenient control
  • Control functions matched to the system hydraulics
  • Easy setup of all control system functions (push-and-turn)
  • Expansion of the complete set of all control systems of additional modules is possible
Fast installation, commissioning and Maintenance
  • Quick installation of the heating circuit adapted to the respective hydraulic circuit for connection to the boiler or for fixing it to the wall
  • Convenient connection of Logalux ST and Logalux SU water heaters with a capacity of 150, 160, 200 and 300 liters to the boiler thanks to the boiler-water heater connection pipe with a loading pump and a non-return valve
  • Burner design without moving parts
  • Easy conversion of the burner to other types of gas

Floor standing gas cast iron heating boiler Buderus Logano G234X with 60 kW atmospheric burner.
New generation of time-tested boilers with modern EMS Plus automation and industrial design from Buderus.

Modern universal concept of the Buderus Logano G234X boiler

  • Low-temperature boiler to DIN EN 297 for modulating boiler water temperature control without base temperature (minimum boiler water temperature)
  • Nominal heating capacity 60 kW
  • The heating boiler is designed to operate on natural gas E or LPG P / B / P
  • Boiler construction with perfectly matched sections made of high quality cast iron
  • Proven and reliable heating boiler with cast iron heat exchanger and atmospheric gas burner
  • Combines with adjacent Logalux SU hot water tanks from the Buderus program
  • Combines with various EMS and EMS Plus management systems from the Buderus program
  • New "industrial" design from Buderus
  • High standardized utilization rate (92%) and low emissions of harmful substances

Work with reduced noise level and low emission of harmful substances

  • Premixed atmospheric gas burner without fan
  • Heating mode without additional noise suppression measures
  • CE mark

Simple and convenient operation with modern weather-compensated automation Logamatic MC110 of EMS Plus standard

  • System controller RC310 or BC30E with touch display and full text menu
  • Human readable text, symbols, status and error information
  • Control functions matched to the system hydraulics
  • Easy step-by-step and intuitive setting of all control system functions
  • It is possible to expand the configuration of the control system for additional modules:
  • KM200 module for remote control via the Internet
  • Mixer module MM100
  • Cascade module MC400 with the ability to control up to 4 boilers
  • For complex systems we recommend using the professional automation of the new generation Logamatic 5000

Fast installation, commissioning and maintenance of the Buderus Logano G234X boiler

  • Quick installation of the heating circuit adapted to the respective hydraulic circuit for connection to the boiler or for fixing it to the wall
  • Convenient connection of Logalux SU water heaters with a capacity of 120, 160, 200 and 300 liters to the boiler thanks to the boiler-water heater connection pipe with a loading pump and a non-return valve
  • Burner design without moving parts
  • Easy conversion of the burner to other types of gas

Buderus Logano G234 60 kW- a heating boiler equipped with a pre-mixed atmospheric gas burner. It is an ideal choice for heating large buildings. With its help, it is possible to organize the supply of heat very economically in those situations where high power is required. In combination with a DHW cylinder, a comfortable DHW system can be easily realized.

The principle of atmospheric combustion is as follows: the gas is automatically fed into the burner together with the atmospheric air required for combustion. In this case, you do not need to use an electric fan, as in other heating boilers... Since the fuel is burned in separate torches, the flame does not come into contact with the burner tube, it does not heat up and therefore will last longer.

Buderus Logano G234 60 kW - hydraulic diagrams using boiler combinations with different burners and control systems:

  1. Logamatic 2107: single stage burner - DHW tank - circulation pump. Equipped with FM 241: heating circuit with mixer. Complete with FM 242: 2-stage or modulating burner. Equipped with FM 244: solar collector.
  2. Logamatic 4211: one, two-stage or modulating burner - DHW tank - circulation pump. Equipment with FM 442: two heating circuits with mixer. Equipped with FM 445: system with external heat exchanger. Equipped with FM 443: solar module. Complete set with FM 446: uniform EIB interface electronic system home control. Equipment with FM 448: general error message.
  3. Logamatic 2101 (operation with constant boiler water temperature): single stage burner.

Buderus Logano G234 60 kW - the advantages of a low temperature gas boiler:

  • Ionization flame control and double solenoid valve;
  • Low level of emission of harmful substances;
  • Low noise work;
  • Compact dimensions and the ability to install a water heater to the right or left of the boiler;
  • High efficiency (up to 93%) due to intensive heat transfer from the heating surfaces of the cast-iron heat exchanger;
  • Ease of installation and service;
  • Reliability and durability of the boiler structure made of gray cast iron;
  • Ease of combination and selection of control systems and storage tanks from the Buderus program;
  • Highly efficient thermal insulation;
  • There are no restrictions on the minimum boiler water temperature.

Buderus Logano G234 60 kW - boiler purpose:

It can be used to heat buildings up to 600 m2, satisfying average heating requirements. With additional equipment, the boiler can be connected to the DHW circuit.

Heating devices with a power of 60 kW are ideal for heating a country cottage, commercial or industrial property. It can operate on natural and liquefied gas, therefore it is suitable for any facility, including those that do not have a central gas supply.

Specifications

  • Rated thermal power (kW): 60;
  • Dimensions HxWxD (mm): 1204x830x726;
  • Boiler water volume (l): 31;
  • No control system;
  • Weight (kg): 310;
  • Allowable overpressure (bar): 4;